Click an image to enlarge. Once enlarged, click to close.

pre-retrofit condition: trusses with a foot of eave overhang and gable end overhangs.

overhangs are removed flush with walls; Roof Guard II added for moisture control

a section of removed eave overhang

remove remaining roofing and gable end overhangs

add Roof Guard II for water protection and air sealing of wall-roof joint

add two layers of 2" polyiso insulation (Tuff R Enerfoil, R=6.5 per inch), onto the roof deck, staggering the joints.

8" screws (Simpson SDWS) through flat 2x4s securing insulation and creating a venting path from eave to ridge. The 2x4s will support a new overhang

add roof decking (5/8" Advantech)

roof decking completed

construct new overhangs

new overhangs and soffits with rough facia

install rake and eave facia